NuTone Fan PFOB 52 User Manual

INSTALLATION INSTRUCTIONS  
READ & SAVE THESE INSTRUCTIONS!  
ALWAYS MOUNT HANGER  
WITH OPENING TOWARD  
TOP OF SLOPE  
“OpenAire”  
MODEL: PFOB-52  
CAUTIONS  
MINIMUM  
1"  
1. Before wiring the paddle fan, turn off the electric power supply  
at the main fuse or circuit breaker box and leave  
it off until the installation is complete.  
MAXIMUM  
25°  
FIGURE 1  
2. Mount the outlet box so it will support a minimum of  
45 pounds. The outlet box must be mounted flush to ceiling.  
Do not use a plastic outlet box.  
3. Do not install paddle fan with less than 7 feet clearance  
between floor and lowest edge of fan blades.  
HEADER  
4. If you are unfamiliar with electric wiring, acquire  
the services of a qualified electrician.  
5. Use proper cable and fittings. Be certain the fan is properly  
grounded. Wiring must comply with national and local  
electrical codes.  
6. Electrical requirements: 120vAC, 60 Hz, single phase,  
1 amp. – without optional lighting accessory.  
RUBBER  
PADS  
7. Fan blades may be cleaned with a mild soap solution. Do not  
use an abrasive cleaner or a strong chemical cleaner.  
8. WARNING: To reduce the risk of fire or electrical shock,  
do not use this fan with any solid-state speed control  
device (NOTE: Refer to NuTone's catalog for appropriate  
speed control switches.)  
OUTLET BOX  
9. WARNING: To reduce the risk of personal injury,  
do not bend the blade brackets when installing the  
brackets, balancing the blades or cleaning the fan. Do not  
insert foreign objects between rotating fan blades.  
10. CAUTION: To reduce the risk of electric shock, connect only  
to supply circuit provided with a ground fault circuit  
interrupter.  
11. CAUTION: To reduce the risk of electric shock, fire or  
personal injury, a light kit must be marked suitable for use  
with this fan and must be marked as suitable for outdoor use.  
12. Do not operate reversing switch while fan blades are in  
motion. Fan should be turned off and blades stopped before  
reversing blade direction.  
SOCKET  
HANGER  
SUPPLEMENTAL  
MOUNTING SCREWS  
FIGURE 2  
ceiling where the maximum angle of the sloped ceiling does  
not exceed 25°.  
2. For any angled ceiling, use appropriate NuTone Extension  
Stems to insure proper clearance between the blades and  
ceiling. See NuTone catalog.  
MOUNTING OUTLET BOX  
Refer to Figure 2.  
LOCATION  
CAUTION: To reduce the risk of personal injury, install the  
supplemental mounting means and use only the hardware  
provided with the fan or use a listed outlet box marked as  
acceptable for fan support. If the combined weight of the  
ceiling fan and any light kit used with it exceeds 35 pounds,  
the fan should be supported independently of the outlet  
box. The weight of your fan is 20 lbs.  
1. Minimum ceiling height: 8 feet. When fan is installed,  
this allows a minimum of 7 feet between the floor and fan  
blades.  
2. The center of the fan must be located at least 32" from  
any vertical surface.  
3. Do not mount fan below, next to or between air ducts, beams  
or any other obstruction which may interfere with the natural  
air flow pattern created by the fan.  
4. Fan can be mounted using down rod or closer to ceiling using  
ceiling cup as close up adapter.  
1. Fan mounts to a standard 4" metallic outlet box or a listed fan  
support box. For damp location mounting, use outlet box listed  
for “Damp Locations”. For outdoor mounting use outlet box  
listed for wet locations.  
MOUNTING ON A SLOPED CEILING  
1. Refer to Figure 1. A paddle fan equipped with a ball and  
hanger bracket assembly can be safely mounted to a sloped  
 
ATTACHING FAN BLADES  
1. Refer to Figure 5. Using three screws and washers  
fasten top and bottom blade bracket to blade as shown.  
2. Refer To Figure 6. Using two motor screws and washers  
provided, secure blade to fan flywheel Repeat for  
remaining blades.  
MOUNTING  
BRACKET  
OPERATION CHECK  
1. Reconnect electrical supply at breaker or fuse box.  
2. Check for proper operation of three speed pull chain switch  
HI – MED – LOW – OFF.  
FIGURE 5  
3. Let fan come to a complete stop, then check operation of  
reversing switch.  
4. For fan balancing see instructions provided with the  
balancing kit.  
RUBBER  
COVER  
OPTIONAL EXTENSION STEM  
Refer to Figure 7.  
To use the optional extension stem (not supplied) follow  
these steps:  
1. Loosen anti-turn screw and slide hanger ball from  
standard stem.  
2. Remove ground wire and pin.  
DOWNROD  
ASSEMBLY  
CANOPY  
3. Attach ground wire and pin to extension stem.  
4. Slide hanger ball onto stem and completely tighten  
anti-turn screw.  
RUBBER  
CANOPY  
NOTE: To avoid possible electric shock, be sure the  
green ground wire has been replace and the anti-turn  
screw has been tightened completely.  
5. Mount extension stem to fan as described in “Mounting  
Fan.  
STOP PIN  
LOCK  
PIN  
SET  
SCREW  
IMPORTANT SAFEGUARDS  
1. Be sure fan is switched off before cleaning it.*  
2. Keep hands, clothing and other objects away from moving  
fan blades.  
3. Exercise close supervision of children if they are present  
when fan is in operation.  
4. Shut off electricity to fan at main fuse or circuit breaker box  
before servicing or working near fan.  
5. Do not operate fan if it has been damaged in any manner.  
Contact your nearest NuTone Authorized Service Center.  
FIGURE 6  
*Fan blades may be cleaned with a mild soap solution. Do not use  
an abrasive cleaner or a strong chemical cleaner.  
DO NOT DISCARD!  
GROUND  
WIRE  
BALL  
HANGER  
ANTI-TURN  
SCREW  
EXTENSION  
STEM  
HITCH PIN  
PIN  
FIGURE 7  
 
Two Year Limited Warranty  
WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period  
of two (2) years from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED  
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
During this two year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.  
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES  
FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident,  
improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.  
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty  
lasts, so the above limitation may not apply to you.  
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS  
WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH  
PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may  
not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.  
WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model  
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present  
evidence of the original purchase date.  
Date of Installation  
Builder or Installer  
Model No. and Product Description  
IF YOU NEED ASSISTANCE OR SERVICE:  
For the location of your nearest NuTone Independent Authorized Service Center:  
Residents of the contiguous United States Dial Free 1-800-543-8687  
Please be prepared to provide:  
Product model number • Date and Proof of purchase • The nature of the difficulty  
Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599.  
Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9.  
Rev. 03/2001  
Product specifications subject to change without notice.  
4820 Red Bank Road, Cincinnati, Ohio 45227  
Printed in Taiwan, Rev. 3/02, Part No. 83012  
 

NEC Computer Monitor PX 61XR3A User Manual
Nextar Digital Photo Frame N5 105 User Manual
Nintendo Video Games 45496741723 User Manual
Numark Industries Car Stereo System 9 Aug User Manual
NuTone Indoor Furnishings QTXEN110SFLT User Manual
Oki Printer 5800Ldn User Manual
Omega Speaker Systems Thermometer OS520 User Manual
Optoma Technology Home Theater Screen DF WW9106F User Manual
Oster Kitchen Utensil 3 Cup Chopper With Accessories User Manual
Panasonic Scanner KV S7075C User Manual